Technology Applications

Mass spectrometry is widely used across industries to deliver precise detection solutions for diverse scenarios.

Enyipu 7700 GC-MS analysis of xylene sample components
Higher Education Research2026-11-13

An益谱 7700 GC-MS analysis of xylene sample components

Use the Anypu 7700 GC-MS to separate and identify sample components. First, locate the peak position of the main component, then analyze other impurities present in the sample besides the main component.

View Details
Method for Determining 11 Novel Neonicotinoid Pesticides in Milk Using Anyeep TQ9120
Food Safety Testing2026-11-13

Method for Determining 11 Neonicotinoid Pesticides in Milk Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to establish a method for the simultaneous detection of 11 new neonicotinoid pesticides in milk. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables the detection and quantification of new neonicotinoid pesticides.

View Details
TQ9120 Triple Quadrupole Mass Spectrometer: Where Does Sensitivity Gain Come From?
Food Safety Testing2026-11-13

TQ9120 Triple Quadrupole Mass Spectrometer: Where Does the Sensitivity Boost Come From?

LC-MS/MS sensitivity, stability, and dynamic range are interdependent. This document outlines the improvements made to the TQ9120 across the three key stages of ion generation, transmission, and detection—including desolvation heating and flow field design, MIF ion transmission structure upgrades, curved collision cell with high-gain detection—as well as software capabilities such as Schedule MRM, auto-tuning, GLP audit trails, and typical application boundaries.

View Details
Agilent 7700 GC-MS Determination of Volatile Organic Compounds in Catalysts
Higher Education Research2026-11-12

Determination of Volatile Organic Compounds in Catalysts Using Anypu 7700 GC-MS

Use the AnYiPu 7700 GC-MS to separate and identify catalyst components using Scan mode, obtain mass spectra for each compound, perform library searches, and conduct qualitative analysis of the catalyst composition.

View Details
Where the bottleneck lies in replacing domestic triple quadrupole GC-MS instruments
Food Safety Testing2026-11-12

Where the bottleneck lies in replacing domestic triple quadrupole GC-MS instruments

The key challenges in replacing domestic triple quadrupole GC-MS systems lie in components that directly determine data quality: the ion source, mass analyzer, and collision cell. Using the ANYEEP TQ8120 as an example, this article explains how ion source ionization efficiency and anti-contamination design, dual-curved four-pole rods, and a 180° collision cell affect selectivity and cross-talk; discusses long-term stability and local service response; and outlines four criteria to determine whether a true replacement has been achieved.

View Details
Method for Determining 11 Per- and Polyfluoroalkyl Substances in Quartz Sand and Soil—Liquid Chromatography-Tandem Mass Spectrometry
Environmental Monitoring2026-11-12

Method for Determining 11 Perfluoroalkyl Compounds in Quartz Sand and Soil by Liquid Chromatography-Tandem Mass Spectrometry

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu to develop a method for the simultaneous detection of 11 per- and polyfluoroalkyl substances (PFAS) in quartz sand and soil. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables reliable detection and quantification of PFAS.

View Details
Determination of Short-Chain Fatty Acids Using the ANYIPU TQ8100 Triple Quadrupole Gas Chromatography-Mass Spectrometry System
Higher Education Research2026-11-11

Determination of Short-Chain Fatty Acids Using the AnYiPu TQ8100 Triple Quadrupole Gas Chromatograph-Mass Spectrometer

Humans lack sufficient enzymes to degrade large amounts of dietary fiber. Undigested dietary fiber ferments to produce short-chain fatty acids (SCFAs), primarily in the colon. SCFAs not only provide energy to colon mucosal cells and promote their metabolism and growth, but also lower colonic pH, inhibit harmful bacteria growth, prevent gut dysfunction, suppress pro-inflammatory factors, and mitigate colon inflammation. Additionally, they inhibit tumor bacterial proliferation, regulate proto-oncogene expression, promote tumor cell differentiation and apoptosis, and exert anti-tumor effects. The specific types and quantities of SCFAs determine their distinct biological impacts. Therefore, establishing the relationship between SCFA profiles (types and concentrations) and human health is crucial. Due to their low molecular weight and boiling points, gas chromatography-mass spectrometry (GC-MS) with excellent qualitative capabilities and high sensitivity serves as an ideal tool for SCFA analysis. However, complex matrices in human blood and feces require robust interference resistance; thus, triple quadrupole GC-MS is better suited for these samples. This study established a method using the AYS TQ8100 triple quadrupole GC-MS system to quantify 7 SCFAs: acetic acid, propionic acid, isobutyric acid, butyric acid, isovaleric acid, valeric acid, and hexanoic acid. Isohexanoic acid served as the internal standard. Qualitative identification was performed using SCAN mode with library search, based on retention time, mass spectra, and characteristic ion pairs. Quantification was achieved via MRM mode using external calibration curves and internal standardization, demonstrating excellent linearity.

View Details
Method for Detecting 4 Flame Retardants in Water Using Liquid Chromatography-Mass Spectrometry
Environmental Monitoring2026-11-11

Method for detecting 4 flame retardants in water using liquid chromatography-tandem mass spectrometry

This study employed the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for quantifying tetrabromobisphenol A and 3 hexabromocyclododecanes in water. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables the detection and quantification of 4 flame retardants in water.

View Details
Detection limit better than 10⁻¹⁴ g; how to read the specs for a single quadrupole GC-MS
Food Safety Testing2026-11-11

Detection limit better than 10⁻¹⁴ g; how to read the specs for a single quadrupole GC-MS

Differences in single quadrupole GC-MS systems are most evident at low concentrations. This article outlines the test conditions required to achieve a limit of detection (LOD) better than 10⁻¹⁴ g (1 pg octafluoronaphthalene, signal-to-noise ratio on m/z 272). It explains the practical implications of this metric for sample preparation and turnaround time, describes how the vacuum system, ion source, mass analyzer, and detector support this performance, and covers CE certification and typical application compatibility.

View Details
7700 Headspace-GC-MS Determination of Ethylene Oxide in Masks
Higher Education Research2026-11-10

7700 Headspace-GC-MS Determination of Ethylene Oxide in Masks

The technical requirements for GB 19083-2010 Medical Protective Masks, YY0469-2011 Surgical Masks, and YY/T 0969-2013 Disposable Medical Masks stipulate that the residual ethylene oxide (EO) content in masks sterilized with EO must not exceed 10 µg/g. This study determined EO levels in masks using headspace gas chromatography-mass spectrometry (HS-GC-MS). The instrument was operated in Scan mode to identify EO based on mass spectra and characteristic ions. Qualitative analysis was performed using Sim mode by comparing retention times and characteristic ion ratios against standards. Quantification was achieved via the external standard method.

View Details
Method for determining the migration of aromatic primary amines from food contact materials and articles using Anyeep TQ9120
Food Safety Testing2026-11-10

Method for Determining the Migration of Aromatic Primary Amines from Food Contact Materials and Articles Using Anyeep TQ9120

This study utilizes the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to establish a method for quantifying the migration of 29 aromatic primary amines in food-contact materials and articles. The method demonstrates excellent linearity, with detection and quantification limits meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of multiple aromatic primary amines in food-contact materials and articles.

View Details
Single injection, 11 perfluorinated compounds: TQ9100 water quality solution
Environmental Monitoring2026-11-10

One-shot injection, 11 perfluorinated compounds: TQ9100 water quality solution

GB 5749-2022 includes PFOA and PFOS in routine water quality indicators, while GB/T 5750.8-2023 and HJ 1333-2023 provide detection guidelines for 11 perfluorinated compounds. This article presents a quantitative method developed using the TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system, covering target analyte scope, solid-phase extraction sample preparation and vessel control, chromatographic and mass spectrometric conditions, delayed column usage to avoid system background contamination, and method validation criteria.

View Details
Method for Determining 59 Plant Growth Regulators in Chinese Herbal Medicines Using Anyeep TQ9120
Higher Education Research2026-11-09

Method for Determining 59 Plant Growth Regulators in Chinese Medicinal Herbs Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 UPLC-MS/MS system from AnyiPu Company to establish a method for detecting multiple plant growth regulators in red ginseng. The method demonstrates excellent linearity, with detection and quantification limits meeting the requirements of the 2025 edition of the Chinese Pharmacopoeia. Using this method and equipment enables the detection and quantification of various plant growth regulators in traditional Chinese medicine herbs.

View Details
Simultaneous determination of 7 macrolide drugs using SQ910 single quadrupole LC-MS
Food Safety Testing2026-11-09

Simultaneous determination of 7 macrolide drugs using SQ910 single quadrupole LC-MS

The challenge in detecting multiple macrolide residues lies not in sensitivity, but in separation and identification. Using the SQ910 single quadrupole LC-MS as an example, this article outlines the chromatographic requirements for 7 macrolides, SIM acquisition and identification boundaries, critical sample preparation points (noting erythromycin's acid sensitivity), instrument conditions, and method validation metrics aligned with standards.

View Details
Determination of Organochlorine Pesticides by Anypu GC-MS/MS
Food Safety Testing2026-11-09

AnYiPu GC-MS/MS Method for Determining Organochlorine Pesticides

Based on the standard "GB 23200.113-2018 National Food Safety Standard: Determination of 208 Pesticide Residues and Their Metabolites in Plant-Derived Foods by Gas Chromatography-Mass Spectrometry", we established a method using triple quadrupole GC-MS to determine 22 organochlorine pesticides. Qualitative analysis was performed via full scan mode based on retention time, mass spectra, and characteristic ions for each pesticide standard. Parent-daughter ion pairs were identified using precursor ion scanning. For multiple ion pairs, optimal collision voltages (5V to 35V) were determined using MRM mode with varying collision energies. Quantification was carried out using the external standard method in MRM mode. We evaluated the linearity between organochlorine pesticide concentrations and peak areas, which showed excellent correlation. Repeatability tests across multiple concentration levels yielded low relative standard deviations, indicating good instrument stability.

View Details
A single-injection trace detection method for 11 perfluorinated compounds in water
Environmental Monitoring2026-11-06

A single-injection trace detection method for 11 perfluorinated compounds in water

Regulatory limits for perfluoro compounds (PFCs) in drinking water are set in μg/L, yet monitoring often requires detection at ng/L levels. This demands a method that excels in enrichment, separation, and background control. Using the TQ9100 UPLC-MS/MS system, this paper outlines solid-phase extraction enrichment, gradient separation, mass spectrometry acquisition parameters, method validation metrics, and key strategies for controlling background contamination for 11 PFCs in water.

View Details
Method for Determination of Pentachlorophenol in Water Using Anyeep TQ120 Online Solid-Phase Extraction
Environmental Monitoring2026-11-06

Method for Determining Pentachlorophenol in Water Using Anyeep TQ9120 Online Solid-Phase Extraction

This study developed a method for detecting pentachlorophenol in water using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeyipu, equipped with an online solid-phase extraction system. The method demonstrated excellent linearity and met relevant standard requirements for detection limits and quantification limits. Using this method and equipment enables reliable detection and quantification of pentachlorophenol in water.

View Details
Amide Pesticides Determination Method Using Agilent Triple Quadrupole GC-MS
Food Safety Testing2026-11-06

Amide Pesticides Determination by GC-MS/MS (Agilent 8950)

With social progress, food safety has become an increasingly critical concern. Pesticide residue testing in food is a routine procedure. Due to complex matrix interferences in food samples, single quadrupole gas chromatography-mass spectrometry (GC-MS) may be insufficient for detecting pesticide residues in such matrices. Therefore, this study employs triple quadrupole GC-MS/MS to analyze pesticide residues in relevant food products. In accordance with the standard "GB 23200.113-2018 National Food Safety Standard: Determination of 208 Pesticides and Their Metabolites Residues in Plant-Derived Foods by Gas Chromatography-Mass Spectrometry," we developed a method using the Anypu TQ8100 GC-MS/MS system to determine 8 amide pesticides. The 8 amide pesticides analyzed include propanil, acetochlor, metolachlor, propisochlor, thiobencarb, pretilachlor, butachlor, and propyzamide. Samples were initially screened using full scan mode. Qualitative identification of each amide pesticide standard was performed based on retention time, mass spectra, and characteristic ions. For acetochlor, precursor-product ion pairs were determined via product ion scanning. Multiple ion pairs were then optimized using different collision energies ranging from 5V to 35V under Multiple Reaction Monitoring (MRM) conditions to achieve the optimal ion pair and corresponding collision energy. Quantification was performed using external standards with MRM mode. We evaluated the linear relationship between amide pesticide concentrations and peak areas, which demonstrated excellent linearity. Reproducibility tests across multiple concentration levels showed low relative standard deviations, indicating good instrument stability. Low-concentration samples exhibited signal-to-noise ratios that fully met requirements, confirming high instrument sensitivity.

View Details
Analyze Baijiu Components with Anypu 7700 GC-MS
Food Safety Testing2026-11-05

Analysis of Baijiu Components Using the Aiyipu 7700 GC-MS

Baijiu from different production processes and vintages exhibits significant flavor variations. This study employs gas chromatography-mass spectrometry (GC-MS) for qualitative analysis to identify the constituent compounds in Baijiu.

View Details
Determination of 9 Phthalates in Water Using Anyeep TQ9120 Online Solid-Phase Extraction
Environmental Monitoring2026-11-05

Determination of 9 Phthalates in Water Using Anyeep TQ9120 Online Solid-Phase Extraction

This study established a method for detecting phthalates in water using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep, equipped with an online solid-phase extraction system. The method demonstrated excellent linearity, and its detection and quantification limits met relevant standard requirements. This method and equipment enable reliable detection and quantification of phthalates in water.

View Details
Method Development for Simultaneous Determination of 8 Quinolones Using SQ910 LC-MS
Food Safety Testing2026-11-05

Method development for simultaneous determination of 8 quinolones using SQ910 LC-MS

Consolidate multiple residues of the same quinolone class into a single chromatography–mass spectrometry workflow for simultaneous qualitative and quantitative analysis in one injection. Using SQ910 LC-MS as an example, this article outlines key design considerations across four stages: compound list and chromatographic conditions, sample preparation, mass spectrometry data acquisition, and validation/confirmation. It covers retention of amphoteric compounds, the impact of pH on recovery rates, and requirements for dual ion-pair confirmation.

View Details
Method for Determining 85 Drugs in Wastewater Using Liquid Chromatography-Mass Spectrometry Coupled with Online Solid-Phase Extraction
Environmental Monitoring2026-11-04

Method for Determining 85 Drugs in Wastewater Using Liquid Chromatography-Mass Spectrometry Coupled with Online Solid-Phase Extraction

This study establishes a method for detecting 85 types of drugs in domestic sewage using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeept, equipped with an online solid-phase extraction system. The method demonstrates excellent linearity, and its detection and quantification limits meet relevant regulatory standards. Using this method and equipment enables the detection and quantification of 85 types of drugs and toxins.

View Details
LC-MS/MS Method for the Detection of 16 Fungal Toxins in Chinese Herbal Medicines
Higher Education Research2026-11-04

Method for Detection of 16 Fungal Toxins in Chinese Herbal Medicines Using Liquid Chromatography-Tandem Mass Spectrometry

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to establish a method for simultaneously detecting 16 mycotoxins in Chinese herbal medicines. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant standard requirements. This approach enables accurate identification and quantification of mycotoxins using the specified method and equipment.

View Details
Determination of residues of 109 pesticides and their metabolites: Method design for TQ8100
Food Safety Testing2026-11-04

Determination of Residues from 109 Pesticides and Their Metabolites: Method Design Using the TQ8100

Integrating 109 pesticides and their metabolites into a single GC-MS/MS method is challenging due to the organization of dozens of retention time windows and hundreds of ion pairs. This paper outlines the method design approach for multi-residue pesticide analysis using the TQ8100 triple quadrupole GC-MS system, covering four key aspects: selectivity margin, compound grouping with time alignment, matrix effect correction, and decision rules with quality control.

View Details
GMA6500/6500K: Why is the cavity designed for 200°C?
Semiconductor Analysis2026-11-03

GMA6500/6500K: Why is the cavity set to 200°C?

The challenge in online small-molecule detection isn't whether a signal can be detected, but whether that signal accurately reflects the true sample composition at the moment of sampling. This article examines two sources of bias—wall adsorption and foreline pump oil contamination—to explain how GMA6500/6500K achieves a full-metal stainless steel chamber at 200°C, constructs its vacuum chain using an oil-free foreline and turbomolecular pump, and demonstrates why vacuum observability is critical for continuous operation and troubleshooting.

View Details
Determination of Thiofuroxan and Carbofuran in Cereals and Grains Using the ANEYU TQ8100 Triple Quadrupole GC-MS/MS System
Food Safety Testing2026-11-03

Analysis of Carbamate Pesticides and Anticoagulant Rodenticides in Cereals and Grains Using the Aneyu TQ8100 Triple Quadrupole Mass Spectrometer

Rodenticide application is a necessary measure for pest control. In recent years, rodenticide testing has gained increasing attention. Detection methods include spectrophotometry, gas chromatography (GC), and GC-mass spectrometry (GC-MS). Spectrophotometry, an early technique, is rarely used for trace analysis today. Gas chromatography suffers from high background interference and cannot confirm target compounds definitively. Currently, coupling GC with MS has become the trend in rodenticide detection. This study establishes qualitative and quantitative methods for detecting phosphamidon and antu in rice, providing a reliable basis for identifying sudden food safety incidents involving rodenticides in food.

View Details
Aniyipu TQ9120 LC-MS/MS Method for Detecting 14 Alkylphenols and Bisphenol A in Water
Environmental Monitoring2026-11-03

AnYiPu TQ9120 LC-MS/MS Method for the Determination of 14 Alkylphenols and Bisphenol A in Water

This study established a method for the simultaneous detection of 14 alkylphenol compounds and bisphenol A in water using Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment enables reliable detection and quantification of alkylphenol compounds.

View Details
Single Quadrupole GC-MS for Determination of Ethyl Carbamate in Food - Anyipu 7700
Food Safety Testing2026-11-03

Single Quadrupole GC-MS for the Determination of Ethyl Carbamate in Food - Anyipu 7700

Referencing GB 5009.223-2014 National Food Safety Standard: Determination of Ethyl Carbamate in Foods, use a gas chromatography-mass spectrometry (GC-MS) system to analyze ethyl carbamate and its internal standard D5-ethyl carbamate mixture. Perform qualitative analysis of the ethyl carbamate standard using Scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantify using Sim mode with D5-ethyl carbamate as the internal standard via the internal standard method.

View Details
LC-MS/MS Method for the Detection of 4 Flame Retardants in Water Using Anyspu TQ9120
Environmental Monitoring2026-11-02

Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) - AnYiPu TQ9120 Method for the Detection of 4 Flame Retardants in Water

This study employed the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for quantifying tetrabromobisphenol A and 3 hexabromocyclododecanes in water. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables the detection and quantification of 4 flame retardants in water.

View Details
LC-MS/MS TQ9120 Method for the Determination of 5 Disinfection Byproducts in Drinking Water
Clinical Testing2026-11-02

LC-MS/MS (Amspec TQ9120) Method for Detecting 5 Disinfection Byproducts in Drinking Water

This study used the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for quantifying 5 disinfection byproducts in drinking water. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standards. Using this method and equipment, we achieved detection and quantification of 5 disinfection byproducts.

View Details
Single Quadrupole GC-MS for Determination of Organochlorine Pesticides in Soil and Sediment - Anyipu 7700
Environmental Monitoring2026-11-02

Single Quadrupole GC-MS System - Anyipu 7700 Determination of Organochlorine Pesticides in Soil and Sediment

Refer to "HJ 835-2017 Determination of Organochlorine Pesticides in Soil and Sediment by Gas Chromatography-Mass Spectrometry." Use a gas chromatograph-mass spectrometer (GC-MS) to analyze the organochlorine pesticide mixture. Qualitative analysis is performed using scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantitative analysis is conducted using the external standard method with SIM mode.

View Details
Four Misconceptions in Developing GC-MS Methods for Food Additives
Food Safety Testing2026-11-02

Four Misconceptions in Developing GC-MS Methods for Food Additives

Acceptance criteria for GC-MS method development of food additives focus on stability at low-concentration detection limits and result reliability in complex matrices. This article identifies four common pitfalls in method development—evalating sensitivity using pure solvent calibration curves, treating cleanup as a universal solution, relying on injection volume to lower detection limits, and monitoring only quantifier ion abundance while ignoring interferences—and provides actionable strategies to avoid them.

View Details
High
Higher Education Research2026-11-02

Hyperbolic Quadrupole Structure

Hyperbolic quadrupole: Provides a more stable ion transmission path.

View Details
Triple Quadrupole LC-MS/MS System - Aisipe TQ9120: Method for Detecting 14 Alkylphenols and Bisphenol A in Water
Environmental Monitoring2026-10-30

Triple Quadrupole LC-MS/MS - AYSPEC TQ9120: Method for Detecting 14 Alkylphenols and Bisphenol A in Water

This study established a method for the simultaneous detection of 14 alkylphenol compounds and bisphenol A in water using Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment enables reliable detection and quantification of alkylphenol compounds.

View Details
Gas Chromatography-Mass Spectrometry (GC-MS) - Anyipu 7700: Determination of 19 Organophosphorus Pesticides
Higher Education Research2026-10-30

Gas Chromatography-Mass Spectrometry (GC-MS) for Determination of 19 Organophosphorus Pesticides by AnyePu 7700

Referencing "HJ 963-2018 Determination of Organophosphorus and Pyrethroid Pesticides in Solid Waste by Gas Chromatography-Mass Spectrometry", the AnYiPu 7700 GC-MS system was used to analyze organophosphorus pesticide mixtures. Qualitative analysis was performed using Scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantification was conducted using Sim mode with external standard calibration.

View Details
Triple Quadrupole Gas Chromatography-Mass Spectrometry (GC-MS/MS) - Aneyu TQ8100 for the Determination of Chloropropanols and Their Fatty Acid Esters, and Glycidol Esters in Food
Food Safety Testing2026-10-30

Triple Quadrupole Gas Chromatograph-Mass Spectrometer - Aniyu TQ100: Determination of Chloropropanols and Their Fatty Acid Esters and Glycidyl Esters in Food

This method follows Part 2, Method 1 (Isotope Dilution-Alkaline Hydrolysis-GC-MS/MS) of the national standard GB5009.191—2024 "Food Safety National Standards: Determination of Chloropropanol and Its Fatty Acid Esters and Glycidyl Esters in Food". Isotopic internal standards are added to extracted fat or oil samples. Alkaline hydrolysis using sodium hydroxide-methanol converts chloropropanol fatty acid esters and glycidyl esters (GE) into chloropropanol and glycidol, respectively. The reaction is terminated with acidified sodium bromide; the generated glycidol is converted to 3-bromo-1,2-propanediol (3-MBPD). After extraction with n-octane, the aqueous phase is derivatized with phenylboronic acid and analyzed using gas chromatography-tandem mass spectrometry for quantification via the internal standard method. During alkaline hydrolysis, a small portion of 3-chloro-1,2-propanediol fatty acid ester (3-MCPDE) yields 3-chloro-1,2-propanediol (3 MCPD), which can convert to glycidol. Upon bromination, this forms the same product as glycidyl esters (3-MBPD). Therefore, when calculating GE content, the amount derived from 3-MCPDE hydrolysis must be subtracted.

View Details
Single Quadrupole GC-MS for Determination of Semi-Volatile Organic Compounds in Soil and Sediment - Anyeepu 7700
Environmental Monitoring2026-10-29

Single Quadrupole GC-MS for Determination of Semi-Volatile Organic Compounds in Soil and Sediment - Anyipu 7700

Refer to "HJ 834-2017 Determination of Semi-Volatile Organic Compounds in Soil and Sediment by Gas Chromatography-Mass Spectrometry." Volatile organic compound (VOC) standard mixtures were analyzed using a gas chromatograph-mass spectrometer (GC-MS). Qualitative analysis was performed based on retention time, mass spectra, and characteristic ion pairs. Quantification was conducted using the external standard method.

View Details
Triple Quadrupole Mass Spectrometer - AnYiPu TQ8100 for Determining 107 Pesticide Residues in Fruits and Vegetables
Food Safety Testing2026-10-29

Triple Quadrupole Mass Spectrometry – Anyipu TQ8100 Determination of 107 Pesticide Residues in Fruits and Vegetables

This study established a method for the simultaneous analysis of 107 pesticide residues in cucumbers using the Anypu TQ8100. Cucumber samples were extracted with acetonitrile, purified via the QuEChERS method, concentrated under nitrogen stream, and reconstituted with ethyl acetate prior to instrumental analysis. Standard curves exhibited excellent linearity within the concentration range of 5–500 µg/L, with correlation coefficients (R) all above 0.995. The limit of quantification ranged from 0.001 to 0.008 mg/kg. At spiked concentrations of 0.005 mg/kg, 025 mg/kg, and 0.05mg/kg, the relative standard deviations (RSD) for the 107 pesticide compounds were 1.07%–13.25%, 1.48%–13.35%, and 1.53%–10.15%, respectively. Recoveries ranged from 75.78.8%–128.46%, 87.29%–128.94%, and 85.47%–113.81%. This method is simple, convenient, highly resistant to interference, and features low detection limits, making it effective for monitoring the content of 107 pesticide residues in fruits and vegetables.

View Details
LC-MS/MS System - Anyeipu TQ9120 for Detection of 16 Fungal Toxins in Traditional Chinese Medicine
Higher Education Research2026-10-29

LC-MS/MS System - Anyeep TQ9120: Method for Detecting 16 Mycotoxins in Chinese Herbal Medicines

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to establish a method for simultaneously detecting 16 mycotoxins in Chinese herbal medicines. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant standard requirements. This approach enables accurate identification and quantification of mycotoxins using the specified method and equipment.

View Details
On-site screening and laboratory confirmation using portable mass spectrometry: a traceable chain of evidence
Higher Education Research2026-10-28

On-Site Screening and Laboratory Confirmation with Portable Mass Spectrometry: A Traceable Chain of Evidence

Environmental monitoring and customs quarantine face the same structural challenge: samples are present, answers must be fast, but conclusions cannot stop at speed. Field screening and laboratory confirmation are not independent processes; they form two segments of a single evidence chain. The first determines which samples warrant confirmatory resources, while the second validates whether those initial judgments can become admissible conclusions. How smoothly this link functions directly determines the practical usability of any mass spectrometry solution in real-world operations.

View Details
Single Quadrupole GC-MS System - Anyi Spectrum 7700 Determination of Aniline Compounds in Water Using GC-MS
Environmental Monitoring2026-10-28

Single Quadrupole GC-MS (AnYiPu 7700): Determination of Aniline Compounds in Water

Referencing "HJ 822-2017 Determination of Aniline Compounds in Water — Gas Chromatography-Mass Spectrometry Method," volatile organic compound (VOC) mix standards were analyzed using a gas chromatograph-mass spectrometer (GC-MS). Qualitative identification was performed based on retention time, mass spectra, and characteristic ion pairs. Quantification was carried out using the external standard method.

View Details
LC-MS/MS System - Anaspec TQ9100 for the Determination of 15 Bile Acids in Human Plasma
Clinical Testing2026-10-28

LC-MS/MS System - AnYiPu TQ9 100 Method for Detection of 15 Bile Acids in Human Plasma

This study used the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously quantifying 15 bile acids in human plasma. The method demonstrated excellent linearity and met relevant regulatory requirements for limits of quantification. Using this method and equipment enables accurate detection and quantification of bile acids.

View Details
LC-MS/MS - Aneespu TQ9 100 Triple Quadrupole LC-MS/MS for the Determination of 53 Perfluorinated Compounds in Water
Environmental Monitoring2026-10-28

LC-MS/MS System - Aiyipu TQ9100 Method for Detection of 53 Perfluorinated Compounds in Water

This study employed Anyeep TQ9100 UPLC-MS/MS system from Anyeep Company to establish a method for simultaneous detection of 53 perfluorinated compounds in water. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables reliable identification and quantification of perfluorinated compounds.

View Details
Selecting a Mass Spectrometer: The Real Weight of Sensitivity, Resolution, and Mass Range
Food Safety Testing2026-10-27

Mass Spectrometer Selection: The Real Weight of Sensitivity, Resolution, and Mass Range

When selecting a mass spectrometer, sensitivity, resolution, and mass range often appear on specification checklists. However, ranking these parameters in isolation from actual analytical tasks frequently yields conclusions that diverge from real-world laboratory performance. This article clarifies the true weighting and interdependencies of these three parameters and explains how to translate them into verifiable methods to confirm capability.

View Details
Method for Determination of Fat-Soluble Vitamins in Human Serum Using the Aisys TQ9100 Liquid Chromatography-Tandem Mass Spectrometry System
Clinical Testing2026-10-27

Method for Determination of Fat-Soluble Vitamins in Human Serum Using the Aiyipu TQ9 LC-MS/MS System

This study established a method for the simultaneous detection of 5 fat-soluble vitamins in human serum using Anyeep TQ9100, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrates excellent linearity, and its limit of quantitation meets relevant standard requirements. Using this method and equipment enables accurate detection and quantification of fat-soluble vitamins.

View Details
LC-MS/MS System - AYES TQ9 Triple Quadrupole LC-MS/MS for the Determination of 17 Perfluorinated Compounds in Drinking Water
Environmental Monitoring2026-10-27

LC-MS/MS System - Anyipu TQ9 Triple Quadrupole Liquid Chromatography-Mass Spectrometry Method for the Determination of 17 Perfluorinated Compounds in Drinking Water

This study established a method for detecting 17 per- and polyfluoroalkyl substances (PFAS) in drinking water using Anyeep TQ9120, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrates excellent linearity, with detection limits and quantification limits meeting relevant regulatory standards. Using this method and equipment enables the identification and quantification of 17 PFAS compounds.

View Details
Environmental Monitoring Station: GC-MS vs. LC-MS for Water Analysis. A Selection Guide for Third-Party Labs from Standard Method Alignment to Pre-treatment Costs
Environmental Monitoring2026-10-26

Environmental Monitoring Station: GC-MS vs. LC-MS for Water Analysis? Equipment Selection Guide for Third-Party Labs, from Standard Method Compatibility to Sample Prep Costs

When third-party testing laboratories expand their scope or update water quality analysis capabilities, GC-MS and LC-MS are frequently included in procurement lists simultaneously. This article compares the selection logic for these two mass spectrometers in environmental monitoring water analysis scenarios across three dimensions: standard method coverage, sample preparation workflows, and consumable maintenance costs, presenting a three-step decision framework.

View Details
LC-MS/MS System - AYES TQ9120 for the Determination of 9 Water-Soluble Plant Growth Regulators in Traditional Chinese Medicines
Clinical Testing2026-10-26

LC-MS/MS System - AYES TQ9120 for the Determination of 9 Water-Soluble Plant Growth Regulators in Traditional Chinese Medicines

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep Company to establish a method for quantifying 9 plant growth regulators in red ginseng. The method demonstrated excellent linearity, with limits of detection and quantification meeting the requirements of the 2025 edition of the Chinese Pharmacopoeia. Using this method and equipment, 9 water-soluble plant growth regulators can be detected and quantified in traditional Chinese medicine herbs.

View Details
Environmental Monitoring Station Selection Dilemma: How Portable Mass Spectrometers Solve Trace Detection Challenges
Environmental Monitoring2026-10-26

Environmental Monitoring Station Selection Dilemma: How Portable Mass Spectrometers Overcome On-Site Trace Detection Challenges

Equipment selection for environmental monitoring stations balances accuracy, efficiency, and usability. Traditional laboratory mass spectrometers often take days from sampling to reporting, making them ill-suited for sudden pollution events. This article outlines the three key challenges in on-site trace detection, explains how portable mass spectrometers address sensitivity, analysis speed, and operational complexity, and provides guidance on use cases and selection criteria for water and air monitoring.

View Details
How to Select a Mass Spectrometer for Therapeutic Drug Monitoring: A Buying Guide from LC-MS Sensitivity to Sample Preparation
Clinical Testing2026-10-23

How to Select a Mass Spectrometer for Therapeutic Drug Monitoring: A Buying Guide from LC-MS Sensitivity to Sample Preparation

Therapeutic drug monitoring (TDM) is critical for managing narrow therapeutic index drugs, including immunosuppressants, antiepileptics, and anticancer agents. LC-MS/MS has become the method of choice in TDM laboratories due to its superior sensitivity, specificity, and capability for multi-drug analysis. This article outlines key selection criteria and validation approaches for mass spectrometers in clinical drug concentration monitoring, focusing on three areas: sensitivity and limit of detection, sample preparation compatibility, and throughput with automation.

View Details
Method for Determining 36 Antibiotic Drugs in Pork Using the Anyeep TQ9120 Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry System
Food Safety Testing2026-10-23

Method for Determining 36 Antibiotics in Pork Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System

This study used the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyi Pu to develop a method for the simultaneous detection of 4 tetracyclines, 19 sulfonamides, and 13 quinolones in animal-derived foods. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables the identification and quantification of tetracyclines, sulfonamides, and quinolones.

View Details
Gas Chromatography-Mass Spectrometry (GC-MS) - Anyipu 7700: Determination of 8 Amide Pesticides in Soil and Sediment
Environmental Monitoring2026-10-23

GC-MS System - Anyipu 7700: Determination of 8 Amide Pesticides in Soil and Sediment

Following "HJ 1053-2019 Determination of 8 Amide Pesticides in Soil and Sediment by Gas Chromatography-Mass Spectrometry," amide pesticide mix standards were analyzed using a GC-MS instrument. Qualitative identification was performed via Scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantification was conducted using Sim mode with the external standard method.

View Details
Comparative Analysis of Mass Spectrometry Applications Across Industries: From Pesticide and Veterinary Residue Testing to Clinical Drug Monitoring
Clinical Testing2026-10-23

Comparative Analysis of Mass Spectrometry Applications Across Industries: From Pesticide and Veterinary Drug Residue Detection to Clinical Drug Monitoring

Mass spectrometry is expanding from the lab to broader applications: screening trace pesticide and veterinary drug residues in food safety, and enabling precise therapeutic drug monitoring in clinical practice. This article compares the core requirements and engineering trade-offs of these two scenarios, analyzing how industry-specific needs shape application strategies and equipment selection under a common mass spectrometry principle.

View Details
How portable mass spectrometers enable rapid contraband screening and expedited customs clearance: A step-by-step operational workflow
Customs Quarantine2026-10-23

How portable mass spectrometers enable rapid contraband screening and expedited clearance in customs quarantine: A step-by-step operational breakdown

Customs quarantine requires high-precision testing within strict time limits, but traditional sample submission methods are too slow. Portable mass spectrometers bring lab-grade trace detection capabilities directly to port sites. This article breaks down the practical workflow for screening prohibited items using portable mass spectrometry in customs quarantine scenarios, covering sampling, sample preparation, instrument analysis, and result interpretation. It also reviews key performance metrics including detection sensitivity, analysis speed, and database coverage.

View Details
Determination of Geosmin and 2-MIB in Water by Headspace Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry
Environmental Monitoring2026-10-22

Determination of Geosmin and 2-Methylisoborneol in Water by Headspace Solid-Phase Microextraction Gas Chromatography-Mass Spectrometry

The new Drinking Water Hygiene Standard (GB5749-2022) has added detection indicators for geosmin (GSM) and 2-methylisoborneol (2-MIB). The detection method follows the headspace solid-phase microextraction gas chromatography-mass spectrometry specified in GB/T32470-2016 or GB/T5750.8-2023. This report used the AnYiPu 7700 GC-MS instrument for testing, with sensitivity, stability, and accuracy all meeting requirements.

View Details
Method for Determining 17 Perfluorinated Compounds in Domestic Drinking Water Using Liquid Chromatography-Mass Spectrometry
Environmental Monitoring2026-10-22

LC-MS/MS Method for the Determination of 17 Perfluorinated Compounds in Drinking Water

This study established a method for detecting 17 per- and polyfluoroalkyl substances (PFAS) in drinking water using Anyeep TQ9120, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrates excellent linearity, with detection limits and quantification limits meeting relevant regulatory standards. Using this method and equipment enables the identification and quantification of 17 PFAS compounds.

View Details
Aniyipu SQ910 LC-MS Simultaneous Determination of 8 Quinolone Drug Residues: Application Method
Food Safety Testing2026-10-22

Aniyu SQ910 LC-MS: Simultaneous Determination of 8 Quinolone Drug Residues

This study established a residue detection method for 8 quinolone drugs using the Aneypu SQ910 single quadrupole LC-MS. Utilizing QuEChERS sample preparation, the method enables simultaneous detection of norfloxacin, ciprofloxacin, enrofloxacin, and other quinolones in a single injection, making it suitable for food safety testing in livestock, poultry, and aquatic products.

View Details
Method for Determining Aloin in Health Food Using Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System
Higher Education Research2026-10-22

Determination of Aloin in Health Food Products Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously detecting aloin in health supplements. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant standard requirements. Using this method and equipment enables reliable detection and quantification of aloin.

View Details
Method for the determination of 16 beta-blockers in milk using Anyeep TQ9120
Food Safety Testing2026-10-21

Method for Determining 16 Beta-Blockers in Milk Using Anyeep TQ9120

This study establishes a method for the simultaneous detection of 16 β-blockers in milk using Anyeep's TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system. The method demonstrates excellent linearity, with limits of detection and quantification meeting relevant standard requirements. This approach enables reliable identification and quantification of β-blockers using the specified instrumentation.

View Details
Aneyu Single Quadrupole Gas Chromatograph-Mass Spectrometer (GC-MS) for Determination of Nitrobenzene Compounds in Water - Aneyu 7700
Environmental Monitoring2026-10-21

AnYiPu Single Quadrupole GC-MS for the Determination of Nitrobenzene Compounds in Water - AnYiPu 7700

To protect the environment and ensure human health, national standards specify methods for detecting nitrobenzene compounds in water. Referencing standard HJ 716-2014 "Determination of Nitrobenzene Compounds in Water—Gas Chromatography-Mass Spectrometry," this study established a detection method using gas chromatography-mass spectrometry (GC-MS) and validated it based on linearity, repeatability, and limit of detection.

View Details
Method for Determining 9 Organophosphates in Aquatic Products Using Anyeep TQ9120
Food Safety Testing2026-10-21

Method for Determining 9 Organophosphates in Aquatic Products Using Anyeep TQ9120

This study used the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu to develop a method for simultaneously detecting 9 organophosphates in aquatic products. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. This method and equipment enable accurate detection and quantification of organophosphates.

View Details
Determination of Common Carbonate Solvents and Additives in Lithium Battery Electrolytes Using the AnYiPu 7700 GC-MS System
Semiconductor Analysis2026-10-21

Determination of Common Carbonate Solvents and Additives in Lithium Battery Electrolytes by AnYiPu 7700 Gas Chromatography-Mass Spectrometry

We established a method using the Anypu 7700 gas chromatography-mass spectrometry system to determine common carbonate solvents and related additives in lithium battery electrolytes. We optimized key parameters, including inlet temperature, temperature programming, and ion source temperature, to finalize the analytical method. Analysis was performed in scan mode, with qualitative identification based on retention time, mass spectra, and characteristic ions, and quantitative determination using the external standard method.

View Details
Single Quadrupole Gas Chromatography-Mass Spectrometry (GC-MS) for the Determination of Polychlorinated Biphenyls (PCBs) in Soil and Sediment
Environmental Monitoring2026-10-21

Single Quadrupole Gas Chromatograph-Mass Spectrometer for Determination of Polychlorinated Biphenyls in Soil and Sediment

Use a gas chromatography-mass spectrometer (GC-MS) to analyze the PCB mixture standard in Scan mode. Identify PCBs based on retention time, mass spectra, and characteristic ion pairs. Quantify using the external standard method in SIM mode. Once the method is established, analyze samples using SIM mode for identification based on peak retention times and characteristic ion ratios, and quantify using the external standard method.

View Details
Method for Determining Polybrominated Diphenyl Ethers Using a 7800 Hyperbolic Quadrupole Mass Spectrometer
Higher Education Research2026-09-28

Method for Determination of Polybrominated Diphenyl Ethers Using 7800 Hyperbolic Quadrupole Mass Spectrometer

Referencing GB/T 26125-2011 for the determination of six restricted substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers) in electrical and electronic products, we adopted a scan mode to qualitatively analyze polybrominated diphenyl ether standards based on retention time, mass spectra, and characteristic ion pairs. We optimized key parameters including injection port temperature, temperature programming, injection method, and ion source temperature. A calibration curve was established using Selected Ion Monitoring (SIM), and the repeatability of the results was evaluated. Ultimately, we developed a method for determining polybrominated diphenyl ethers using the Anyspec 7800 hyperbolic quadrupole gas chromatography-mass spectrometry system.

View Details
Method for Determining 16 Benzimidazole Drugs Using Anyeep TQ9100
Clinical Testing2026-09-28

Method for Determining 16 Benzimidazole Drugs Using Anyeep TQ9100

This study established a method for the simultaneous detection of 16 benzimidazole drugs using Anyeep TQ9100, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant regulatory standards. This approach enables reliable detection and quantification of benzimidazole drugs.

View Details
Method for Determination of Bifenthrin Residues in Animal-Derived Foods Using Anyeep TQ9120
Food Safety Testing2026-09-28

Method for Determining Residues of Benzovindiflupyr in Animal-Derived Foods Using Anyeep TQ9120

This study established a method for detecting flusilazole residues in milk using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant regulatory standards. This approach enables reliable detection and quantification of flusilazole in animal-derived food products.

View Details
Determination of 11 Perfluorinated Compounds in Water Using Anyeep TQ9120 Online Solid-Phase Extraction
Environmental Monitoring2026-09-24

Determination of 11 Perfluoroalkyl Compounds in Water Using Anyeep TQ9120 Online Solid-Phase Extraction

This study developed a method for detecting 11 perfluorinated compounds in water using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep, equipped with an online solid-phase extraction system. The method demonstrated excellent linearity and met relevant standard requirements for limits of detection and quantification. Using this method and equipment enables reliable identification and quantification of multiple perfluorinated compounds.

View Details
Method for Determining 18 Beta-Adrenergic Agonists in Pork Using Anyeep TQ9120
Food Safety Testing2026-09-23

Method for Determining 18 β-Agonists in Pork Using Anyeep TQ9120

This study established a method for the simultaneous detection of 18 β-adrenergic agonists in pork using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables the identification and quantification of β-adrenergic agonists.

View Details
Aniyu 7700 GC-MS Method for Determining 2,4,6-tert-Butylphenol
Higher Education Research2026-09-23

Agilent 7700 GC-MS/MS Determination of 2,4,6-tert-butylphenol

An AnYiPu 7700 gas chromatography-mass spectrometry (GC-MS) method was established for the determination of 2, 4, and 6-tert-butylphenol. Chromatographic conditions, including column oven temperature, injection port temperature, temperature program, injection mode, and ion source temperature, were optimized. Qualitative analysis was performed using Scan mode based on retention time, mass spectra, and characteristic ion pairs for 2, 4, and 6-tert-butylphenol standards. Quantitative analysis was conducted using Sim mode with external calibration. The linearity between concentration and peak area was evaluated across two concentration ranges, demonstrating excellent linearity to meet the detection requirements for samples at varying concentrations. Reproducibility tests on multiple samples at different concentrations showed low relative standard deviations, indicating good instrument stability.

View Details
Method for Determining Residues of Erythromycin and Its Degradation Products in Bee Products Using Anyeep TQ9120
Food Safety Testing2026-09-23

Method for Determining Residues of Erythromycin and Its Degradation Products in Bee Products Using Anyeep TQ9120

This study established a method for detecting erythromycin and its degradation products in bee products using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment, erythromycin and its degradation products in bee products can be effectively detected and quantified.

View Details
Complete solution for determining residues of 331 pesticides and their metabolites in plant-derived foods according to GB23200.121-2021, using Anyeep TQ9100.
Food Safety Testing2026-09-22

Complete solution for determining residue levels of 331 pesticides and their metabolites in plant-derived foods according to GB23200.121-2021, using the Anyeep TQ9100.

This study establishes an ultra-high-performance liquid chromatography-tandem triple quadrupole mass spectrometry (UHPLC-MS/MS) method for detecting 236 pesticide residues in common plant-derived foods, using the Anyeep TQ9100 system from Anyeep. The method was validated on matrices including green peppers, pears, rice, cooking oil, and tea, demonstrating excellent linearity and repeatability. Detection limits and quantification limits meet the requirements of GB23200.121-2021. This approach enables sensitive detection and accurate quantification of pesticide residues in fruits, vegetables, grains, oilseeds, and tea.

View Details
Determination of Pentachlorothiophenol Using AnYiPu 7700 GC-MS
Higher Education Research2026-09-22

Determination of Pentachlorothiophenol using AnYiPu 7700 GC-MS

The Toxic Substances Control Act (TSCA) is a U.S. federal law enacted by Congress in 1976 to regulate the production and use of toxic substances. The U.S. Environmental Protection Agency (EPA) is responsible for implementing TSCA's chemical controls. On 1, 6, 2021, the EPA published final rules on five persistent, bioaccumulative, and toxic (PBT) chemicals in the Federal Register. These five substances are decabromodiphenyl ether (DecaBDE), triphenyl phosphate (PIP), pentachlorothiophenol (PCTP), hexachlorobutadiene (HCBD), and 2,4,6-TTBP-tert-butyl phenol (2,4,6).

View Details
Method for Determining 11 Perfluorinated Compounds in Quartz Sand and Soil Using Anyeep TQ9120
Environmental Monitoring2026-09-21

Method for Determining 11 Perfluorinated Compounds in Quartz Sand and Soil Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu to develop a method for the simultaneous detection of 11 per- and polyfluoroalkyl substances (PFAS) in quartz sand and soil. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables reliable detection and quantification of PFAS.

View Details
AnYiPu 7700 Single Quadrupole GC-MS for the Determination of 7 Phthalates
Higher Education Research2026-09-21

Analysis of 7 Phthalates Using AnYiPu7700 Single Quadrupole GC-MS

Referencing "GB/T 29786-2013 Determination of Dimethyl Phthalate in Electrical and Electronic Products — Gas Chromatography-Mass Spectrometry", dimethyl phthalate standard mixtures were analyzed using a gas chromatography-mass spectrometer. Qualitative analysis was performed via Scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantitative determination was conducted using the external standard method under SIM mode.

View Details
Method for Determining 4 Flame Retardants in Water Using Anyeep TQ9120
Higher Education Research2026-09-21

Method for Determining 4 Flame Retardants in Water Using Anyeep TQ9120

This study employed the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for quantifying tetrabromobisphenol A and 3 hexabromocyclododecanes in water. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables the detection and quantification of 4 flame retardants in water.

View Details
Method for Determining 53 Perfluorinated Compounds in Water Using Anyeep TQ9100
Environmental Monitoring2026-09-20

Method for Determining 53 Perfluorinated Compounds in Water Using Anyeep TQ9100

This study utilized the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeyu Company to develop a method for simultaneously detecting 53 perfluorinated compounds in water. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment enables reliable detection and quantification of perfluorinated compounds.

View Details
AnYiPu 7700 Single Quadrupole GC-MS for the Determination of 18 Polycyclic Aromatic Hydrocarbons in Electronic and Electrical Products
Semiconductor Analysis2026-09-20

AnYiPu 7700 Single Quadrupole GC-MS for Determination of 18 Polycyclic Aromatic Hydrocarbons in Electronic and Electrical Products

Reference to "GB/T 29784.2-2013 Determination of polycyclic aromatic hydrocarbons in electrical and electronic products — Part 2: Gas chromatography-mass spectrometry method". A mixture of 18 polycyclic aromatic hydrocarbon standards was analyzed using a gas chromatography-mass spectrometer (GC-MS). Qualitative analysis was performed based on retention time, mass spectra, and characteristic ion pairs in Scan mode. Quantitative analysis was conducted using the external standard method in SIM mode. The effects of solvent, injection port temperature, ion source temperature, injection technique, and liner type on the method were evaluated to determine the optimal conditions.

View Details
Method for Determining 5 Disinfection Byproducts in Drinking Water Using Anyeep TQ9120
Environmental Monitoring2026-09-20

Method for Determining 5 Disinfection Byproducts in Drinking Water Using Anyeep TQ9120

This study used the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for quantifying 5 disinfection byproducts in drinking water. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standards. Using this method and equipment, we achieved detection and quantification of 5 disinfection byproducts.

View Details
Method for Determining 17 Perfluorinated Compounds in Drinking Water Using Anyeep TQ9120
Environmental Monitoring2026-09-18

Method for Determining 17 Perfluorinated Compounds in Drinking Water Using Anyeep TQ9120

This study established a method for detecting 17 per- and polyfluoroalkyl substances (PFAS) in drinking water using Anyeep TQ9120, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrates excellent linearity, with detection limits and quantification limits meeting relevant regulatory standards. Using this method and equipment enables the identification and quantification of 17 PFAS compounds.

View Details
AnYiPu 7700 Single Quadrupole GC-MS for Determination of Plant Growth Regulators in Fertilizers
Higher Education Research2026-09-18

AnYiPu 7700 Single Quadrupole Gas Chromatography-Mass Spectrometry for Determination of Plant Growth Regulators in Fertilizers

Reference GB/T 42954-2023 Determination of plant growth regulators in fertilizers—Gas chromatography-mass spectrometry method. Volatile organic compound (VOC) mixed standards were analyzed using a GC-MS instrument. Qualitative identification was performed based on retention time, mass spectra, and characteristic ion pairs in Scan mode. Quantification was carried out using the external standard method in SIM mode.

View Details
Selecting Mass Spectrometers for University Research: Applicability Boundaries of GC-MS and LC-MS
Higher Education Research2026-09-18

Selecting Mass Spectrometers for University Research: Applicability Boundaries Between GC-MS and LC-MS

GC-MS and LC-MS are the two most widely used mass spectrometry platforms in university research. Their underlying principles, applicable sample types, and analytical objectives differ fundamentally. Selecting the wrong instrument can lead to substandard data quality or, in severe cases, require a complete overhaul of your project's analytical strategy.

View Details
Why Mass Spectrometry is Essential for Pesticide and Veterinary Drug Residue Detection: GC-MS Principles and Workflow Breakdown
Food Safety Testing2026-09-17

Why Mass Spectrometry is Essential for Pesticide and Veterinary Residue Detection: Deconstructing GC-MS Principles and Workflows

The core of pesticide and veterinary drug residue testing is identifying trace unknown molecules within complex food matrices. Gas chromatography-mass spectrometry (GC-MS) integrates separation and identification into a single analytical workflow, serving as the primary confirmatory method under current national standards.

View Details
Anaypu 7700 GC-MS Method for Qualitative Analysis of Amine Compounds
Higher Education Research2026-09-17

AnYiPu 7700 GC-MS Method for Qualitative Analysis of Amine Compounds

The AnYiPu 7700 GC-MS was used to qualitatively analyze the customer's sample. Parameters such as inlet temperature, temperature program, and ion source temperature were optimized to establish a definitive qualitative method for the sample. A scan mode was employed; mass spectra obtained from scanning were matched against a spectral library for identification. The composition of sample 1 includes: methanol (CAS 67-56-1), ethylenediamine (CAS 107-15-3), ethanolamine (CAS 141-43-5), piperazine (CAS 110-85-0), diethylenetriamine (CAS 111-40-0), hydroxyethyl ethylenediamine (CAS 111-41-1), N-aminoethylpiperazine (CAS 140-31-8), and hydroxyethylpiperazine (CAS 103-76-4). Sample 2 contains the same components as sample 1.

View Details
Complete solution for determining residues of 331 pesticides and their metabolites in plant-derived foods according to GB23200.121-2021, using Anyeep TQ9100.
Higher Education Research2026-09-17

Complete solution for determining residue levels of 331 pesticides and their metabolites in plant-derived foods according to GB23200.121-2021, using the Anyeep TQ9100.

This study establishes an ultra-high-performance liquid chromatography-tandem triple quadrupole mass spectrometry (UHPLC-MS/MS) method for detecting 236 pesticide residues in common plant-derived foods, using the Anyeep TQ9100 system from Anyeep. The method was validated on matrices including green peppers, pears, rice, cooking oil, and tea, demonstrating excellent linearity and repeatability. Detection limits and quantification limits meet the requirements of GB23200.121-2021. This approach enables sensitive detection and accurate quantification of pesticide residues in fruits, vegetables, grains, oilseeds, and tea.

View Details
Method for Determining Residues of 9 Penicillin Drugs Using Anyeep TQ9100
Clinical Testing2026-09-16

Method for detecting 9 types of penicillin residues using Anyeep TQ9100

This study utilized the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep Company to establish a method for the simultaneous detection of nine penicillin drugs. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of penicillin drugs.

View Details
Method for Determining 16 Mycotoxins in Grains Using Anyeep TQ9120
Food Safety Testing2026-09-16

Method for Determining 16 Mycotoxins in Grains Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously detecting 16 fungal toxins in cereals. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant regulatory standards. Using this method and equipment enables accurate detection and quantification of fungal toxins.

View Details
Suzhou Anyipu 7700 GC-MS Determination of n-Alkanes
Higher Education Research2026-09-16

Determination of n-Alkanes by Suzhou Anyipu 7700 GC-MS

n-Alkanes in petroleum products are important chemical feedstocks. While many methods exist for determining n-alkane content, gas chromatography (GC) is the most common. This study employs gas chromatography-mass spectrometry (GC-MS) for the qualitative and quantitative analysis of n-alkanes.

View Details
Method for Determining 11 Novel Neonicotinoid Pesticides in Milk Using Anyeep TQ9120
Food Safety Testing2026-09-15

Method for Determining 11 Neonicotinoid Pesticides in Milk Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to establish a method for the simultaneous detection of 11 new neonicotinoid pesticides in milk. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables the detection and quantification of new neonicotinoid pesticides.

View Details
Method for Determining 6 Psychotropic Drugs in Bovine Blood Using Anyeep TQ9100
Higher Education Research2026-09-15

Method for Determining 6 Psychotropic Drugs in Bovine Blood Using Anyeep TQ9100

This study utilized the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously detecting 6 psychoactive drugs in bovine blood. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant regulatory standards. Using this method and equipment enables reliable detection and quantification of psychoactive drugs.

View Details
Analysis of Dioctyl Terephthalate (TOTM) Plasticizer using AnYiPu 7700 GC-MS
Higher Education Research2026-09-15

Aniyu 7700 GC-MS Analysis of Di(2-octyl)phthalate TOTM

Phthalate diester TOTM single standard was detected using GC-MS in Scan mode. Qualitative analysis of the TOTM standard was performed based on retention time, mass spectrum, and characteristic ions. Quantification was conducted in SIM mode.

View Details
Determination of Rose Essential Oil Components Using ANEYU 7700 GC-MS
Higher Education Research2026-09-14

Determination of Rose Essential Oil Components Using AnYiPu 7700 GC-MS

Use the Enshi 7700 GC-MS to separate and identify components of rose essential oil. Perform full-scan mass spectrometry for qualitative analysis based on library matching results.

View Details
Method for Determining 18 Beta-Adrenergic Agonists in Pork Using Anyeep TQ9120
Food Safety Testing2026-09-14

Method for Determining 18 β-Agonists in Pork Using Anyeep TQ9120

This study established a method for the simultaneous detection of 18 β-adrenergic agonists in pork using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables the identification and quantification of β-adrenergic agonists.

View Details
Method for Determining 16 Mycotoxins in Grains Using Anyeep TQ9120
Food Safety Testing2026-09-11

Method for Determining 16 Mycotoxins in Grains Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously detecting 16 fungal toxins in cereals. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant regulatory standards. Using this method and equipment enables accurate detection and quantification of fungal toxins.

View Details
AnYiPu 7700 Headspace GC-MS for Determining Volatile Organic Compounds in Glue
Higher Education Research2026-09-11

Determination of Volatile Organic Compounds in Glue Using AnYiPu 7700 Headspace Gas Chromatography-Mass Spectrometry

The customer provided a viscous adhesive sample and requested qualitative identification of the volatile organic compounds (VOCs) present. The Aneeshi 7700 Headspace-GC/MS system was used to separate and identify the components in the adhesive.

View Details
Method for Determining 4 Nitrofurans Metabolites Using Anyeep TQ9100
Higher Education Research2026-09-11

Method for Determining 4 Nitrofuran Metabolites Using Anyeep TQ9100

This study utilized the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu to develop a method for simultaneously detecting 4 nitrofuran metabolites. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant regulatory standards. Using this method and equipment enables reliable detection and quantification of nitrofuran metabolites.

View Details
Enyipu 7700 GC-MS analysis of xylene sample components
Higher Education Research2026-09-10

An益谱 7700 GC-MS analysis of xylene sample components

Use the Anypu 7700 GC-MS to separate and identify sample components. First, locate the peak position of the main component, then analyze other impurities present in the sample besides the main component.

View Details
Method for Determining 9 Organophosphates in Aquatic Products Using Anyeep TQ9120
Food Safety Testing2026-09-10

Method for Determining 9 Organophosphates in Aquatic Products Using Anyeep TQ9120

This study used the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu to develop a method for simultaneously detecting 9 organophosphates in aquatic products. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. This method and equipment enable accurate detection and quantification of organophosphates.

View Details
Method for Determining Residues of Erythromycin and Its Degradation Products in Bee Products Using Anyeep TQ9120
Food Safety Testing2026-09-10

Method for Determining Residues of Erythromycin and Its Degradation Products in Bee Products Using Anyeep TQ9120

This study established a method for detecting erythromycin and its degradation products in bee products using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment, erythromycin and its degradation products in bee products can be effectively detected and quantified.

View Details
Method for Determining Residues of Tilmicosin in Animal-Derived Foods Using Anyeep TQ9120
Food Safety Testing2026-09-09

Method for Determining Tylosin Residues in Animal-Derived Foods Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyiipu to establish a method for detecting ciamycin residues in beef. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of ciamycin in animal-derived foods.

View Details
Agilent 7700 GC-MS Determination of Volatile Organic Compounds in Catalysts
Higher Education Research2026-09-09

Determination of Volatile Organic Compounds in Catalysts Using Anypu 7700 GC-MS

Use the AnYiPu 7700 GC-MS to separate and identify catalyst components using Scan mode. Acquire mass spectra for each compound, perform library searches, and conduct qualitative analysis of the catalyst components.

View Details
Determination of Short-Chain Fatty Acids Using the ANYIPU TQ8100 Triple Quadrupole Gas Chromatography-Mass Spectrometry System
Higher Education Research2026-09-09

Determination of Short-Chain Fatty Acids Using the AnYiPu TQ8100 Triple Quadrupole Gas Chromatograph-Mass Spectrometer

Humans lack sufficient enzymes to degrade large amounts of dietary fiber. Undigested dietary fiber ferments to produce short-chain fatty acids (SCFAs), which are primarily generated in the colon. SCFAs not only provide energy for intestinal mucosal cells, promoting cell metabolism and growth, but also lower colonic pH, inhibit harmful bacteria, prevent gut dysfunction, suppress pro-inflammatory factors, and mitigate colitis. Additionally, they inhibit tumor bacterial proliferation, control proto-oncogene expression, promote tumor cell differentiation and apoptosis, and exert anti-tumor effects. The specific types and quantities of SCFAs determine their physiological impacts. Therefore, research into SCFAs can establish relationships between their profiles (types and concentrations) and human health. Due to their low molecular weight and boiling point, gas chromatography-mass spectrometry (GC-MS) is an excellent tool for SCFA analysis due to its superior qualitative capabilities and high sensitivity. However, biological matrices such as blood and feces are complex; triple quadrupole GC-MS offers superior interference resistance, making it more suitable for analyzing these complex samples. This study developed a method using the Amsys TQ8100 triple quadrupole GC-MS system to quantify 7 SCFAs: acetic acid, propionic acid, isobutyric acid, butyric acid, isovaleric acid, valeric acid, and hexanoic acid. Heptanoic acid was used as the internal standard. Qualitative analysis was performed using SCAN mode with library matching based on retention time, mass spectra, and characteristic ion pairs. Quantification was achieved using MRM mode with internal standard calibration, demonstrating excellent linearity.

View Details
7700 Headspace-GC-MS Determination of Ethylene Oxide in Masks
Higher Education Research2026-09-08

7700 Headspace-GC-MS Determination of Ethylene Oxide in Masks

GB 19083-2010 Technical Requirements for Medical Protective Masks, YY0469-2011 Surgical Masks, and YY/T 0969-2013 Disposable Medical Masks. According to the physicochemical specifications of these standards, the ethylene oxide (EO) residue in masks sterilized by EO must not exceed 10 µg/g. This study used headspace gas chromatography-mass spectrometry (HS-GC-MS) to determine EO content in masks. EO standard was analyzed via HS-GC-MS using scan mode; EO was identified based on mass spectra and characteristic ions. Qualitative analysis was performed using SIM mode by comparing retention times and ion ratios. Quantification was conducted using the external standard method.

View Details
Method for Determining 9 Water-Soluble Plant Growth Regulators in Chinese Herbal Medicines Using Anyeep TQ9120
Higher Education Research2026-09-08

Method for Determining 9 Water-Soluble Plant Growth Regulators in Chinese Medicinal Herbs Using Anyeep TQ9120

This study employed Anyeep's TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system to develop a method for quantifying multiple plant growth regulators in ginseng root. The method demonstrates excellent linearity, with limits of detection and quantification meeting the requirements of the 2025 edition of the Chinese Pharmacopoeia. Using this method and equipment, we can detect and quantify 9 water-soluble plant growth regulators in traditional Chinese medicine herbs.

View Details
Determination of Organochlorine Pesticides by Anypu GC-MS/MS
Food Safety Testing2026-09-08

AnYiPu GC-MS/MS Method for Determining Organochlorine Pesticides

Based on the standard "GB 23200.113-2018 National Food Safety Standard: Determination of Residues of 208 Pesticides and Their Metabolites in Plant-Derived Foods by Gas Chromatography-Mass Spectrometry," we developed a method using triple quadrupole GC-MS to determine 22 organochlorine pesticides. The 19 target compounds are α-BHC, hexachlorobenzene, β-BHC, γ-BHC, δ-BHC, heptachlor, aldrin, epoxide heptachlor B, α-chlordane, endosulfan I, γ-chlordane, dieldrin, p,p'-DDE, isodrin, endosulfan II, p,p'-DDD, o,p'-DDT, isodrin aldehyde, endosulfan sulfate, p,p'-DDT, isodrin ketone, methoxychlor, and mirex. Qualitative analysis was performed via full scan mode based on retention time, mass spectra, and characteristic ions. Parent-daughter ion pairs were identified using sub-scan mode. For multiple ion pairs, collision voltages ranging from 5V to 35V were optimized under MRM conditions to select the optimal ion pairs and corresponding collision voltages. Quantification was conducted using external standards with MRM. We evaluated the linear relationship between concentration and peak area for each pesticide, which demonstrated excellent linearity. Repeatability tests across multiple concentrations showed low relative standard deviations, confirming good instrument stability.

View Details
Amide Pesticides Determination Method Using Agilent Triple Quadrupole GC-MS
Higher Education Research2026-09-07

Amide Pesticides Determination by GC-MS/MS (Agilent 8950)

With societal progress, food safety has garnered increasing attention. Detecting pesticide residues in food is a routine procedure; however, complex matrices can limit the effectiveness of single quadrupole GC-MS for residue analysis. Therefore, we employed triple quadrupole GC-MS to determine pesticide residues in relevant food products. Following the standard "GB 23200.113-2018 National Food Safety Standard: Determination of 208 Pesticide Residues and Their Metabolites in Plant-Derived Foods by Gas Chromatography-Mass Spectrometry," we established an analytical method using the Aispu TQ8100 LC-MS/MS system to quantify 8 amide pesticides. These include propanil, acetochlor, alachlor, metolachlor, propyzamide, pretilachlor, butachlor, and propisochlor. Qualitative analysis was performed via full-scan mode based on retention time, mass spectra, and characteristic ions. For acetochlor, a product ion scan was used to identify precursor-product ion pairs. Multiple ion pairs were then optimized using MRM with collision voltages ranging from 5V to 35V. Quantification was conducted using the external standard method with MRM. We evaluated the linear relationship between amide pesticide concentrations and peak areas, which demonstrated excellent linearity. Repeatability tests across multiple concentration levels showed low relative standard deviations, indicating good instrument stability. Low-concentration samples exhibited signal-to-noise ratios that fully met requirements, confirming high instrument sensitivity.

View Details
Method for Determination of Bifenthrin Residues in Animal-Derived Foods Using Anyeep TQ9120
Food Safety Testing2026-09-07

Method for Determining Residues of Benzovindiflupyr in Animal-Derived Foods Using Anyeep TQ9120

This study established a method for detecting flusilazole residues in milk using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant regulatory standards. This approach enables reliable detection and quantification of flusilazole in animal-derived food products.

View Details
Analyze Baijiu Components with Anypu 7700 GC-MS
Food Safety Testing2026-09-07

Analysis of Baijiu Components Using the Aiyipu 7700 GC-MS

White liquors from different production processes and vintages exhibit significant flavor variations. This study employs gas chromatography-mass spectrometry (GC-MS) for qualitative analysis to identify the constituent compounds in white liquor.

View Details
Method for Determining 9 Water-Soluble Plant Growth Regulators in Chinese Herbal Medicines Using Anyeep TQ9120
Higher Education Research2026-09-04

Method for Determining 9 Water-Soluble Plant Growth Regulators in Chinese Medicinal Herbs Using Anyeep TQ9120

This study employed Anyeep's TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system to develop a method for quantifying multiple plant growth regulators in ginseng root. The method demonstrates excellent linearity, with limits of detection and quantification meeting the requirements of the 2025 edition of the Chinese Pharmacopoeia. Using this method and equipment, we can detect and quantify 9 water-soluble plant growth regulators in traditional Chinese medicine herbs.

View Details
Determination of 11 Perfluorinated Compounds in Food Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System
Food Safety Testing2026-09-04

Determination of 11 perfluoroalkyl compounds in food using the Anyeep TQ9120 UHPLC-MS/MS system

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeypu to establish a method for the simultaneous detection of 11 perfluorinated compounds in food. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables reliable detection and quantification of perfluorinated compounds.

View Details
Analysis of Ethyl Carbamate in Food Using the Aniyipu 7700 Single Quadrupole Gas Chromatograph-Mass Spectrometer
Food Safety Testing2026-09-04

Aniyu 7700 Single Quadrupole GC-MS for Determination of Ethyl Carbamate in Food

Refer to "GB 5009.223-2014 National Food Safety Standard: Determination of Ethyl Carbamate in Foods." Use gas chromatography-mass spectrometry (GC-MS) with a mixed standard of ethyl carbamate and its internal standard D5-ethyl carbamate. Perform Scan mode analysis for qualitative identification based on retention time, mass spectrum, and characteristic ion pairs. Conduct Sim mode analysis for quantitative determination using the internal standard method with D5-ethyl carbamate as the internal standard.

View Details
Determination of 3 preservatives in food using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system
Food Safety Testing2026-09-03

Method for Determining 3 Preservatives in Food Using the Anyeep TQ9120 Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry System

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously detecting 3 preservatives in food. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables accurate detection and quantification of preservatives.

View Details
AnYiPu 7700 Single Quadrupole Gas Chromatograph-Mass Spectrometer for the Determination of Organochlorine Pesticides in Soil and Sediment
Environmental Monitoring2026-09-02

EnyiPu 7700 Single Quadrupole GC-MS for Determination of Organochlorine Pesticides in Soil and Sediment

According to "HJ 835-2017 Determination of Organochlorine Pesticides in Soil and Sediments by Gas Chromatography-Mass Spectrometry", organochlorine pesticide mix standards were analyzed using a gas chromatography-mass spectrometry system. Qualitative analysis was performed based on retention time, mass spectra, and characteristic ions in Scan mode. Quantification was conducted using the external standard method in Sim mode.

View Details
Method for Determining Bromate Content in Flour, Bread, and Drinking Water Using Anyeep TQ9100
Food Safety Testing2026-09-02

Method for Determining Bromate Content in Flour, Bread, and Drinking Water Using Anyeep TQ9100

This study utilized the Anyeep TQ9100 triple quadrupole mass spectrometer from Anyeep Company to develop a method for detecting bromate in flour, bread, and drinking water. The method demonstrates excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of bromate in food and drinking water.

View Details
Method for Determining Chlorate and Perchlorate Content in Milk Powder Using Anyeep TQ9100
Food Safety Testing2026-09-02

Method for Determining Chlorate and Perchlorate Content in Milk Powder Using Anyeep TQ9100

This study utilized the Anyeep TQ9100 triple quadrupole mass spectrometer from Anyiipu Company to establish a method for detecting chlorate and perchlorate in milk powder. The method demonstrates excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of chlorate and perchlorate in milk powder.

View Details
Quantify 15 bile acids in human plasma using Anyeep TQ9100
Clinical Testing2026-09-01

Quantify 15 bile acids in human plasma using Anyeep TQ9100.

This study used the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously quantifying 15 bile acids in human plasma. The method demonstrated excellent linearity and met relevant regulatory requirements for limits of quantification. Using this method and equipment enables accurate detection and quantification of bile acids.

View Details
Analysis of 19 Organophosphorus Pesticides Using AnYiPu7700 Single Quadrupole GC-MS
Food Safety Testing2026-08-31

AnYiPu 7700 Single Quadrupole GC-MS for the Determination of 19 Organophosphorus Pesticides

Reference "HJ 963-2018: Determination of Organophosphorus and Pyrethroid Pesticides in Solid Waste (Total of 47 Types) by Gas Chromatography-Mass Spectrometry". Use the Anyspu 7700 GC-MS to analyze the organophosphorus pesticide mixture standard. Qualitative analysis is performed using Scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantitative analysis is conducted using Sim mode with the external standard method.

View Details
Method for Determining 18 Beta-Adrenergic Agonists in Pork Using Anyeep TQ9120
Food Safety Testing2026-08-31

Method for Determining 18 β-Agonists in Pork Using Anyeep TQ9120

This study established a method for the simultaneous detection of 18 β-adrenergic agonists in pork using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables the identification and quantification of β-adrenergic agonists.

View Details
Suzhou Ayespu Semiconductor Industry Application Solution (II): GMA6500 Small Molecule Online Mass Spectrometry & RGA6500 Analysis Module
Semiconductor Analysis2026-08-31

Suzhou Anyipu Semiconductor Industry Application Solution (II): GMA500 Online Mass Spectrometry for Small Molecules & RGA500 Analysis Module

GMA6500 Small Molecule Online Mass Spectrometry & RGA6500 Analysis Module

View Details
Method for Determining 18 Beta-Adrenergic Agonists in Pork Using Anyeep TQ9120
Food Safety Testing2026-08-28

Method for Determining 18 β-Agonists in Pork Using Anyeep TQ9120

This study established a method for the simultaneous detection of 18 β-adrenergic agonists in pork using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables the identification and quantification of β-adrenergic agonists.

View Details
AnYiPu 7700 Single Quadrupole Gas Chromatography-Mass Spectrometry for the Determination of Pyrethroid Pesticides in Water
Environmental Monitoring2026-08-28

AnYiPu 7700 Single Quadrupole GC-MS for Determination of Pyrethroid Pesticides in Water

Refer to "HJ 753-2015 Determination of Cypermethrin and Pyrethroid Pesticides in Water by Gas Chromatography-Mass Spectrometry." Use a gas chromatography-mass spectrometer (GC-MS) to analyze pyrethroid pesticide mixtures. Qualitative analysis is performed using Scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantification is conducted via external standard calibration in Sim mode. Once the method is established, samples are analyzed using Sim mode for qualitative identification based on peak retention times and characteristic ion ratios, with quantification performed using the external standard method.

View Details
Method for Determining Chloramphenicol Residues in Milk Using Anyeep TQ9120
Food Safety Testing2026-08-28

Method for Determining Chloramphenicol Residues in Milk Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu to establish a method for detecting chloramphenicol residues in milk. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of chloramphenicol in milk.

View Details
AnYiPu 7700 Single Quadrupole GC-MS for Determination of Semi-Volatile Organic Compounds in Soil and Sediment
Environmental Monitoring2026-08-27

AnYiPu 7700 Single Quadrupole GC-MS for Determination of Semi-Volatile Organic Compounds in Soil and Sediment

Reference "HJ 834-2017 Determination of Semi-Volatile Organic Compounds in Soil and Sediment by Gas Chromatography-Mass Spectrometry." Volatile organic compound (VOC) mixed standards were analyzed using a gas chromatography-mass spectrometer (GC-MS). VOCs were qualitatively identified based on retention time, mass spectra, and characteristic ion pairs, and quantitatively determined using the external standard method.

View Details
Method for Determination of Pentachlorophenol in Water Using Anyeep TQ120 Online Solid-Phase Extraction
Environmental Monitoring2026-08-27

Method for Determining Pentachlorophenol in Water Using Anyeep TQ9120 Online Solid-Phase Extraction

This study developed a method for detecting pentachlorophenol in water using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeyipu, equipped with an online solid-phase extraction system. The method demonstrated excellent linearity and met relevant standard requirements for detection limits and quantification limits. Using this method and equipment enables reliable detection and quantification of pentachlorophenol in water.

View Details
Method for Determining 35 Quinolone and Sulfonamide Antibiotics in Water Using Anyeep TQ9120 Online Solid-Phase Extraction
Environmental Monitoring2026-08-27

Determination of 35 quinolone and sulfonamide antibiotics in water using Anyeep TQ9120 online solid-phase extraction

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep, equipped with an online solid-phase extraction module, to establish a method for quantifying multiple antibiotics in water. The method demonstrated excellent linearity and met relevant standard requirements for detection limits and quantification limits. Using this method and equipment, 35 quinolone and sulfonamide antibiotics can be detected and quantified.

View Details
Determination of 22 Environmental Estrogens in Water Using Anyeep TQ9120 Online Solid-Phase Extraction
Environmental Monitoring2026-08-26

Method for Determining 22 Environmental Estrogens in Water Using Anyeep TQ9120 Online Solid-Phase Extraction Technology

This study established a method for detecting multiple environmental estrogens in water using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system coupled with an online solid-phase extraction system. The method demonstrated excellent linearity, and its detection limit and quantification limit meet relevant standard requirements. Using this method and equipment enables the detection and quantification of 22 types of environmental estrogens.

View Details
Semiconductor Industry Application Solution (I)
Thermal Desorption-7700GCMS & VOC/SVOC
Semiconductor Analysis2026-08-26

Semiconductor Industry Application Solution (I) Thermal Desorption - 770 GC-MS & VOC/SVOC

Thermal Desorption-7700 GC-MS System (Lab Offline): Specialized in medium-to-large molecule VOCs/SVOCs, photoresist pyrolysis products, encapsulant outgassing, and cleanroom AMC contamination. Solves complex organic pollution tracing challenges that online mass spectrometry cannot resolve.

View Details
Method for determining 4 tetracycline drugs using Anyeep TQ9100
Clinical Testing2026-08-26

Method for determining 4 tetracycline drugs using Anyeep TQ9100

This study utilized the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for the simultaneous detection of 4 tetracycline antibiotics. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant regulatory standards. Using this method and equipment enables reliable detection and quantification of tetracycline drugs.

View Details
AnYiPu 7700 Single Quadrupole GC-MS for Determination of 8 Amide Pesticides in Soil and Sediment
Environmental Monitoring2026-08-25

Enyipu 7700 Single Quadrupole GC-MS for the Determination of 8 Amide Pesticides in Soil and Sediment

Reference "HJ 1053-2019 Determination of 8 Amide Pesticides in Soil and Sediment by Gas Chromatography-Mass Spectrometry". Detect amide pesticide mix standards using GC-MS in Scan mode. Qualitative analysis is performed based on retention time, mass spectra, and characteristic ion pairs for amide pesticide standards. Quantitative analysis is conducted using the external standard method in SIM mode.

View Details
Determination of aniline compounds in water using 7700 gas chromatography-mass spectrometry
Environmental Monitoring2026-08-25

Determination of aniline compounds in water using 7700 gas chromatography-mass spectrometry

Reference "HJ 822-2017 Determination of Aniline Compounds in Water by Gas Chromatography-Mass Spectrometry." Volatile organic compound (VOC) mixtures were analyzed using a GC-MS system. Qualitative identification was performed based on retention time, mass spectra, and characteristic ion pairs for VOC standards. Quantification was conducted using the external standard method.

View Details
Method for Determining 9 Organophosphates in Aquatic Products Using Anyeep TQ9120
Food Safety Testing2026-08-25

Method for Determining 9 Organophosphates in Aquatic Products Using Anyeep TQ9120

This study used the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from AnyiPu to develop a method for simultaneously detecting 9 organophosphates in aquatic products. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. This method and equipment enable accurate detection and quantification of organophosphates.

View Details
Determination of Geosmin and 2-MIB in Water by Headspace Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry
Environmental Monitoring2026-08-21

Determination of Geosmin and 2-Methylisoborneol in Water by Headspace Solid-Phase Microextraction Gas Chromatography-Mass Spectrometry

The new Drinking Water Hygiene Standard (GB5749-2022) has added geosmin (GSM) and 2-methylisoborneol (2-MIB) as testing indicators. The detection methods follow the headspace solid-phase microextraction gas chromatography-mass spectrometry specified in GB/T32470-2016 or GB/T5750.8-2023. This report utilized the Amspec 7700 GC-MS system for analysis, with instrument sensitivity, stability, and accuracy all meeting requirements.

View Details
Method for Determination of Lipid-Soluble Vitamins in Human Serum Using Anyeep TQ9100
Clinical Testing2026-08-19

Method for Determining Lipid-Soluble Vitamin Content in Human Serum Using Anyeep TQ9100

This study established a method for the simultaneous detection of 5 fat-soluble vitamins in human serum using Anyeep TQ9100, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrates excellent linearity, and its limit of quantitation meets relevant standard requirements. Using this method and equipment enables accurate detection and quantification of fat-soluble vitamins.

View Details
Method for Determining Residues of Tilmicosin in Animal-Derived Foods Using Anyeep TQ9120
Food Safety Testing2026-08-18

Method for Determining Tylosin Residues in Animal-Derived Foods Using Anyeep TQ9120

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyiipu to establish a method for detecting ciamycin residues in beef. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of ciamycin in animal-derived foods.

View Details
Method for Determining 6 Psychotropic Drugs in Bovine Blood Using Anyeep TQ9100
Higher Education Research2026-08-17

Method for Determining 6 Psychotropic Drugs in Bovine Blood Using Anyeep TQ9100

This study utilized the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously detecting 6 psychoactive drugs in bovine blood. The method demonstrated excellent linearity, with detection limits and quantification limits meeting relevant regulatory standards. Using this method and equipment enables reliable detection and quantification of psychoactive drugs.

View Details
Determination of 4 antioxidants in steamed wheat products using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system
Food Safety Testing2026-08-17

Method for Determining 4 Antioxidants in Steamed Flour Products Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System

This study established a method to simultaneously detect 4 antioxidants in steamed flour products using Anyeep's TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system. The method demonstrated excellent linearity, and its detection limits met relevant regulatory standards. This approach enables reliable identification and quantification of antioxidants.

View Details
Method for Determining Residues of 9 Penicillin Drugs Using Anyeep TQ9100
Clinical Testing2026-08-16

Method for detecting 9 types of penicillin residues using Anyeep TQ9100

This study utilized the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep Company to establish a method for the simultaneous detection of nine penicillin drugs. The method demonstrated excellent linearity, with limits of detection and quantification meeting relevant standard requirements. Using this method and equipment enables the detection and quantification of penicillin drugs.

View Details
Chemisorption Analyzer Coupled with ANYIPU Small-Molecule Mass Spectrometry: TPD-MS Online Analysis for In-Depth Catalyst Mechanism Research
Semiconductor Analysis2026-08-15

Chemisorption Analyzer Coupled with Amspec Small-Molecule Mass Spectrometry: TPD-MS Online Analysis for Deep Catalyst Mechanism Research

In the field of multiphase catalysis, chemisorption analyzers are the standard instruments for characterizing catalyst surface acidity, active sites, and adsorption/desorption behavior. Traditional chemisorption analyzers rely on TCD thermal conductivity detectors to collect signals, which only reflect total gas quantity changes. They cannot distinguish mixed gas components or identify intermediates and byproducts generated during temperature ramping, severely limiting the depth of catalytic reaction mechanism analysis. By integrating a chemisorption analyzer with an AMS small-molecule mass spectrometer to create a TPD-MS (Temperature Programmed Desorption-Mass Spectrometry) online coupled system, we establish a new dynamic online analysis solution. This approach connects the complete data chain of "temperature-product type-product concentration" for surface processes on catalysts, providing critical characterization capabilities for the development of novel catalytic materials.

View Details
Fully Self-Developed Breakthrough | ANYEEP TQ8120 GC-MS/MS Sets New Benchmark for Domestic Triple Quadrupole GC-MS Alternatives
Higher Education Research2026-08-14

Fully Self-Developed Breakthrough | ANYEEP TQ8120 GC-MS/MS Sets New Standard for Domestic Triple Quadrupole Mass Spectrometry

For years, China's high-end triple quadrupole gas chromatography-tandem mass spectrometry (GC-MS/MS) market has been heavily reliant on imported equipment. Imported instruments come with high acquisition costs, long lead times for core components, and steep maintenance fees. Moreover, their closed underlying technology makes it difficult to align with China's national standard testing methods and local detection needs for complex sample matrices, creating a major bottleneck for many testing laboratories and research institutions. To meet the critical industry demand for domestic substitution, Anyeep has launched the ANYEEP TQ8120 GC-MS/MS system. Designed to tackle the core challenges of replacing foreign technology, this instrument follows a path of full control over core technologies. From its EI ion source and dual-curved quadrupole mass analyzer to its high-efficiency collision cell, every key component is fully developed in-house. The system achieves an optimal balance of ultra-high sensitivity, long-term operational stability, and intelligent user experience, delivering a cost-effective, domestically produced trace analysis solution for environmental, food, pharmaceutical, and industrial applications.

View Details
Determination of 8 N-Nitrosamines in Food Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System
Food Safety Testing2026-08-10

Determination of 8 N-nitrosamines in food using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system

This study established a method for simultaneously detecting 8 N-nitrosamines in food using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrated excellent linearity, with detection and quantification limits meeting relevant standard requirements. Using this method and equipment enables the identification and quantification of antioxidants.

View Details
Determination of Nitrobenzene Compounds in Water Using the Anypu Single Quadrupole Gas Chromatography-Mass Spectrometry System
Environmental Monitoring2026-08-07

Determination of Nitrobenzene Compounds in Water Using the APEX Single Quadrupole Gas Chromatography-Mass Spectrometer

To protect the environment and ensure human health, national standards specify detection methods for nitrobenzene compounds in water. Referencing standard HJ 716-2014 "Determination of Nitrobenzene Compounds in Water—Gas Chromatography-Mass Spectrometry," this study developed a GC-MS-based method for detecting these compounds and validated it by evaluating linearity, repeatability, and limits of detection.

View Details
Quantify 15 bile acids in human plasma using Anyeep TQ9100
Clinical Testing2026-08-07

Quantify 15 bile acids in human plasma using Anyeep TQ9100.

This study used the Anyeep TQ9100 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep to develop a method for simultaneously quantifying 15 bile acids in human plasma. The method demonstrated excellent linearity and met relevant regulatory requirements for limits of quantification. Using this method and equipment enables accurate detection and quantification of bile acids.

View Details
Determination of Polychlorinated Biphenyls in Soil and Sediment
Environmental Monitoring2026-08-07

Determination of Polychlorinated Biphenyls in Soil and Sediment

Analyze the polychlorinated biphenyls (PCBs) mixture standard using a gas chromatography-mass spectrometry (GC-MS) system. Perform qualitative analysis via Scan mode based on retention time, mass spectra, and characteristic ion pairs. Quantify using the external standard method in SIM mode. Once the method is established, analyze samples using SIM mode for qualitative identification based on peak retention times and characteristic ion ratios, and quantify using the external standard method.

View Details
Analysis of Volatile Organic Compounds in Water Using the ANEYIPU Single Quadrupole Gas Chromatograph-Mass Spectrometer
Environmental Monitoring2026-08-03

Analysis of Volatile Organic Compounds in Water Using the ANEYIPU Single Quadrupole Gas Chromatograph-Mass Spectrometer

As living standards improve, public concern over environmental safety, food quality, and pharmaceutical security grows. Volatile organic compounds (VOCs) in water are a standard testing parameter. Following national standards, we established a method for measuring VOCs in water using headspace gas chromatography-mass spectrometry (GC-MS).

View Details
Method for Determination of Sulfonamides and Antibacterial Synergists Residues in Bee Products Using the Anyeep TQ9120 Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry System
Food Safety Testing2026-07-30

Method for Determination of Sulfonamides and Antimicrobial Synergists Residues in Bee Products Using Anyeep TQ9120 Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry System

This study establishes a method for the simultaneous detection of sulfonamides and antibacterial synergists in bee products using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep. The method demonstrates excellent precision and accuracy, meeting all relevant regulatory standards. Using this approach with the specified equipment enables the detection and quantification of 25 types of sulfonamides.

View Details
Determination of 6 sweeteners in fruit juices using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system
Food Safety Testing2026-07-16

Determination of 6 sweeteners in fruit juices using the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system

This study utilized the Anyeep TQ9120 ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyi Pu Company to establish a method for the simultaneous detection of 6 sweeteners in fruit juices. The method demonstrated excellent linearity, and its limits of detection and quantification meet relevant regulatory standards. Using this method and equipment enables the identification and quantification of sweeteners.

View Details
Determination of Acrylamide in Toothpaste Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System
Higher Education Research2026-07-07

Determination of Acrylamide in Toothpaste Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System

This study employed Anyeep TQ9120, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep, to develop a method for detecting acrylamide in toothpaste matrices. The method demonstrated excellent linearity and met the required detection and quantification limits per relevant standards. Using this method and equipment enables both the detection and quantification of acrylamide.

View Details
Determination of Acrylamide in Toothpaste Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System
Higher Education Research2026-07-07

Determination of Acrylamide in Toothpaste Using the Anyeep TQ9120 Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry System

This study employed Anyeep TQ9120, an ultra-high-performance liquid chromatography-tandem mass spectrometry system from Anyeep, to develop a method for detecting acrylamide in toothpaste matrices. The method demonstrated excellent linearity and met the required detection and quantification limits per relevant standards. Using this method and equipment enables both the detection and quantification of acrylamide.

View Details
Jiangsu ICP License No. 18014087-1