Determination of Common Carbonate Solvents and Additives in Lithium Battery Electrolytes by AnYiPu 7700 Gas Chromatography-Mass Spectrometry

We established a method using the Anypu 7700 gas chromatography-mass spectrometry system to determine common carbonate solvents and related additives in lithium battery electrolytes. We optimized key parameters, including inlet temperature, temperature programming, and ion source temperature, to finalize the analytical method. Analysis was performed in scan mode, with qualitative identification based on retention time, mass spectra, and characteristic ions, and quantitative determination using the external standard method.
Experimental Conditions
gas phase conditions
Injection mode: Split; Split ratio: 20:1; Injection port temperature: 280°C;
Column: DB-17MS 30m × 0.25mm × 0.25µm, Constant Flow Mode | Column Flow Rate: 1mL/min
Oven temperature program: 40°C (1 min) → 10°C/min → 75°C (0 min) → 30°C/min → 50°C (1 min)
30℃/min² 50℃ (2 min)
Mass Spectrometry Conditions
Ion source: 280°C; transfer line: 280°C; solvent delay: 2 min;
Experimental Results
Prepared mixed standard solutions at concentrations 10, 50, 100, 250, and 500mg/L using dichloromethane as the solvent. Analyzed via GC-MS in full-scan mode with external standard quantification, demonstrating excellent linearity. The lowest concentration point (10mg/L) was injected consecutively 8 times; relative standard deviations (RSD) of peak areas were all below 4.6%, indicating good instrument repeatability. Instrument detection limits (IDLs) for target compounds were all below 1.4mg/L.
The study evaluated the linearity of the target compound across the concentration range of 10–50 mg/L, demonstrating good linearity. Linearity at the lowest concentration point 10mg/L was assessed via consecutive injections; the relative standard deviation (RSD) of peak areas for 8 consecutive injections remained below 5%, indicating excellent instrument reproducibility. The instrumental detection limits (IDL) for the target compounds were all below 1.4mg/L.