Analysis of Baijiu Components Using the Aiyipu 7700 GC-MS

Baijiu from different production processes and vintages exhibits significant flavor variations. This study employs gas chromatography-mass spectrometry (GC-MS) for qualitative analysis to identify the constituent compounds in Baijiu.
Experimental Conditions
Chromatographic Parameters
Injection mode: Direct; Injection volume: 1 µL; Injection port mode: Split; Injection port temperature: 250°C; Split ratio:
10: 1; Column Flow Rate: 1.0mL/min (Constant Flow).
Column: DB-WAX 60m×0.25mm×0.25µm
Oven temperature program: 37°C (2 min) 3°C/min 70°C (1 min) 6°C/min 130°C (0 min) 10°C/min
220°C (10 min).
Mass Spectrometry Parameters
Ion source temperature: 240°C; Transfer line: 240°C; Solvent delay: 0.1min; Filament off time:
8.3min~9.5min; Scan mode: Full scan (Scan); Mass range: 25~200 amu; Ionization energy: 70 eV; Lamp
Leakage current: 100µA; EM voltage: 900V
Experimental Results
Take an appropriate amount of Baijiu and perform detection and analysis according to the experimental conditions above. Table 1 lists the organic compounds in Baijiu other than the main component, ethanol. Based on area percentage, the major components are ethyl acetate, ethyl hexanoate, ethyl lactate, acetic acid, and hexanoic acid.